troubleshooting:projectors:3d_eye_swap_error [2022/10/18 15:38] – [Test Pattern Note:] apenngracetroubleshooting:projectors:3d_eye_swap_error [2024/10/10 17:32] (current) andrew
Line 31: Line 31:
  
 ==== List of cables that correspond to projectors: ==== ==== List of cables that correspond to projectors: ====
 +
 +//The order below match the order on the crestron.//
  
   * V020 - Left Wall   * V020 - Left Wall
Line 41: Line 43:
   * V030 - Floor Right   * V030 - Floor Right
  
 +
 +==== Another thing to try: ====
 +
 +Another thing to try is to go into the Nvidia synchronization settings.  Click on another monitor other than mosaic.  DO NOT CLICK apply.  Then click on mosaic again.  Then click apply.  Sometimes that can have an affect according to Jason Keeney